Pulmonary Function Tester A9

Pulmonary Function Tester A9

 

img6

Intended Use

Pulmonary function tester A9 is a professional system for detecting lung diseases. lt consists of a portable pulmonary function tester host and application software. lt can conduct comprehensive pulmonary ventilation function tests, including forced vital capacity, vital capacity, maximum Voluntary Ventilation, and diastolic medication before and after comparison tests.


The test is conducted under the guidance of a doctor in a clinic, doctor's office, or hospital. it is suitable for people over 4 years old who can cooperate with the test. it can be used for the detection and diagnosis of bronchial asthma, chronic
obstructive pulmonary disease and other diseases.

 

Highlights

  1. The differential pressure flow sensor has high accuracy, good repeatability, stable performance, long service life, simple maintenance, and low cost;
  2. Supports USB and Bluetooth data transmission methods, and can freely choose PC or APP test software according to the usage scenario;
  3. Automatically give ATS2019 quality control ratings, intelligently interpret lung function reports, and provide analysis suggestions;
  4. Breathing tubes can be completely immersed and sterilized, reducing cross-infection, and is compatible with common bacterial filters.

 

Complete, Professional, and Flexible Testing System

img7

  1. Multi-mode and multi-parameters: Forced Vital Capacity (FVC), Slow Vital Capacity (SVC), Maximum Voluntary Ventilation (MVV), bronchodilation test, with more than 30 measurement parameters;
  2. Supports capacity/3 flow calibration and verification to ensure the accuracy and stability of measurement data;
  3. Supports multiple prediction models, including adult prediction (ECCS93), children prediction (Zapletel), etc.;
  4. Supports standard follow-up questionnaires for common respiratory diseases: including CAT, mMRC, COPD-SQ, etc.

 

Comprehensive Quality Control of Pulmonary Function Tests

img8

  1. Standardized quality control of operations: real-time monitoring of forced exhalation duration, guidance on stopping exhalation when forced end-expiration flow is lower than 0.025L/s, guidance on zero point calibration of pressure difference, and a dynamic reminder of tidal baseline;
  2. Automatic quality control rating: A/B/C/D/E/U/F;
  3. Result interpretation: Intelligent interpretation of pulmonary function reports, automatically evaluates test results and gives disease analysis suggestions, standardized clinical scales assist diagnosis and treatment decisions.

 

Technical Parameters

Flow

Range0-16L/s; Accuracy: <5%

Volume

Range0-10L; Accuracy :<2.5%

Resistance

0.15kPa/(L/s)

Test parameters

FVCFEVO.5FEV1FEV3FEV6V backextrapol.exFIVC
FIV1PEFFEF25%FEF50%FEF75%FEF25%-75%PIF
FIF50%FET100%V backextrapol.inVC maxICIRV
VTERVMVBFMVV, et

 

Optional accessories

 

3L Calibration Cylinder

 

图片包含 图示

描述已自动生成

Disposable Filters

 

图片包含 机械, 游戏机

描述已自动生成